10 Tips for Successful Cell Based Assays

Cell based assays have emerged as an effective and strong addition to compliment other technologies that are suitable for drug discovery and high throughput screening. Cell based assays offer a biologically relevant substitute to predict the response of a drug on an organism and while initially used mostly for secondary screening, are now progressively being used for primary screens. This has been extremely valuable in screening all types of compounds. In addition, they are used in many research areas, providing knowledge about biological targets and pathways in the whole cell.
Choosing a cell-based screening assay requires special understanding, manipulations, and considerations. This will eliminate potential sources of noise and variability that can deteriorate assay performance. The following are 10 Tips describing some of the important factors to consider when choosing a cell-based assay to ensure running a successful cell based assay:





1. Choosing cell types

Choosing the right cell type to study is a key factor to obtaining relevant results and to achieving a successful research outcome. Different cell types (Primary cells vs. Cell lines) have been known to generate different biomarkers, which can influence the results of the assay. Primary cells (HUVECs, hepatocytes, etc.) are perfect options when performing in vitro studies, however they are difficult to grow and be transfected. When performing cell viability assays that use a metabolite, it is important to know that cell lines generally have a higher metabolic rate than primary cells. Concurrently, primary cells have a higher spontaneous rate of death, which can cause background when running a cytotoxicity assay. Therefore the cell type of choice will dictate the assay conditions.


2. Understanding Cell Apoptosis

Understanding of the cell death process and mechanism is very important when studying a specific cell type and deciding on a suitable assay. During apoptosis the cells shut down metabolism, lose membrane integrity, release cytoplasmic material into the surrounding medium, and eventually die. Certain biomarkers of apoptosis such as caspase activity are transiently expressed, have very short half-lives, and therefore are only detectable within a limited range of time. Ultimately understanding the cell death process in the specific cell type could help define the experimental design and endpoint selection.


3. The Edge Effect

Edge effects are known as factors that contribute to the deterioration of assay performance. The causes of edge effect are complex and can generate high plate rejection rate in screening runs. Cells in the wells around the edge of the plate may react differently than the inner wells due to a temperature differential, which is created when the plate is placed in the incubator (1). Stacking plates on top of each other and evaporation during long incubation times also produce the edge effect. In order to avoid this effect it is recommended to duplicate or triplicate the experimental samples, monitor the timing, plate order, and plate position in the incubator during the assay, and making sure that the incubator temperature is evenly distributed (1). Another approach to significantly reduce the edge effect is to incubate newly seeded plates at room temperature before placing them in an incubator (2).


4. Avoid Contamination

Biological contaminates such as mold, bacteria, and other cells can cause inconsistent and irreproducible results. Assess the lab environment and be sure to cover the plates during incubation. Even the slightest contamination can ruin weeks of research. Moreover, wipe clean media bottles, pipettes, and other pertinent materials with ethanol prior to running the assay. Carry over is another problem caused by improper washing of old pipette tips. Washing old tips with EtOH and DMSO is one common way laboratories cut cost. However this can lead to carryover of DMSO into the wells resulting in much lower signal. Therefore it is recommended to use new tips.


5. Regulate Temperature and CO2


Controlling temperature and CO2 is crucial to maintaining cell viability in cell-based assays. Cells left at room temperature before incubation can lead to increased background, resulting in reduced signal to background ratios (1). This can be corrected by stirring the cells on ice while adding them to small batches of assay plates at a time. This will minimize the amount of time the cells are exposed to room temperature and improve the overall results of the assay. Many cell lines cannot tolerate exposure to room temperature, whereas other cells require lengthy room temperature treatments for the assay. Ultimately every cell line is different and therefore optimal experimental conditions need to be determined according to each cell line. CO2 is also a factor when performing cell based assays. If the CO2 concentration is too high during incubation, the activity of the cells can be adversely affected. Small variations in environmental factors such as temperature and CO2 can have a very large impact on the outcome of the assay (1).


6. Pipetting Errors

Pipetting inaccuracies are very common mistakes, which can lead to variable results due to poor viability, cell death, and false cytotoxicity. Cells should be gently and evenly distributed from well to well or when preparing frozen aliquots. Pipette calibrations should be performed to prevent inaccuracies in the experimental data.


7. Optimize Cell Density

Consistent cell density in samples allows for accurate determination of sensitivity, range of the assay, and most importantly trustworthy data. Wells with sparse cell cultures can lead to higher detection sensitivity. Conversely high cell density cultures can result in higher background signals and may demand longer exposure times with the compound being tested, thus leading to inaccurate results. To optimize cell density, a standard curve of differing cell numbers should be generated to assay for viability and cytotoxicity. This will provide an accurate idea of the cell density needed before introducing test compounds into the assay.


8. Assay Controls

Using a control is a very important step in the experimental design. It determines if the assay is functioning properly. In addition, control samples will provide reference points to compare the data, in order to study any variables in the samples. Several controls need to be considered including positive controls, negative controls (untreated cells), and no cells. Ultimately these controls will provide a reference point for data analysis and give greater confidence in the biomarker being studied.


9. Instrumentation and Detection Parameters

The detection instrument being used may also affect the result of the assay. Filter sets, instrument gain, and microplate types are all important variables to keep in mind when running a successful cell-based assay. If there is no change in the fluorescent signal, while increasing the number of treated vs. untreated cells, this can be due to an incorrect filter setting. It is recommended to confirm the Ex/Em maxima of a given fluorophore with the appropriate filter. Large error bars between treated and untreated samples can be the result of the instrument gain being set too low. Clear bottomed plates allow for cell morphology to be analyzed prior to the assay, however these plates can lead to increased crosstalk. Black sided well plates should be used for fluorescent assays to reduce scatter, overlap of signal, and crosstalk.


10. Data Analysis

Assay performance can be analyzed in a number of different ways. The signal-to-background ratio or signal window (S/B = mean signal / mean background) and the signal-to-noise ratio (S/N = mean signal – mean background / Standard Deviation of background) are often used as measures of assay performance. Unfortunately though, these ratios do not take assay variability into consideration. Calculating the Z’ statistic, or score, provides a measure of assay quality, while taking into account both the signal-to-noise ratio and assay variability. A higher Z’ value conveys greater reproducibility and precision of the assay. A perfect assay has a Z’ value of 1. For a high throughput screening assay a Z’ value of > 0.5 is generally considered acceptable. Although the Z’ statistic was originally derived for evaluating HTS assays, it is a general measure of assay quality and can be applied to any assay (3).



Enzo Life Sciences offers a comprehensive product portfolio of cell based assays for advancing your research in drug discovery, mitochondrial dysfunction, Wnt pathway modulators, autophagy, and many more popular areas of research. Related products include our CELLestial kits, drug discovery kits, small molecules, and compound libraries, some of which are listed below.



Share this TechNote

Never miss a new TechNote!

Receive our TechNotes as soon as they are published.


Follow Us!

 
comments powered by Disqus

References:

  1. Maddox C, Rasmussen L, White EL. Adapting Cell-Based Assays to the High Throughput Screening Platform: Problems Encountered and Lessons Learned. JALA Charlottesv. Va. 2008; 13: 168-173.
  2. Lundholt B, Pagliaro L, Scudder K. A Simple Technique for Reducing Edge Effect in Cell-Based Assays. J. Biomol. Screen. 2003; 8: 566-70.
  3. Broadway N. How to Develop Assays: 5 Considerations and 8 Fundamentals. Mater Methods. 2012; 2: 121..

Related Products

LEADING LIGHT® Wnt Reporter Assay Starter Kit 

Chemiluminescent cell-based assay for discovering Wnt pathway modulators
FUNC, Chemiluminescence, HTS | Print as PDF
 
ENZ-61001-0001 96 wells 1,248.00 USD
Do you need bulk/larger quantities?
 

MITO-ID® Membrane potential cytotoxicity kit  

A Real-time Mitochondrial membrane Potential Assay with Superior Sensitivity
HTS, Microplate | Print as PDF
 
ENZ-51019-KP002 1 Kit 330.00 USD
Do you need bulk/larger quantities?
 

CYTO-ID® Autophagy detection kit 

A no-transfection, quantitative assay for monitoring autophagy in live cells
Flow Cytometry, Fluorescence microscopy, Fluorescent detection, HTS | Print as PDF
 
ENZ-51031-0050 50 tests 268.00 USD
 
ENZ-51031-K200 200 tests 553.00 USD
Do you need bulk/larger quantities?
 

PROTEOSTAT® Aggresome detection kit  

Robust, quantitative detection of aggresomes relevant to the study of neurodegenerative disease, liver disease and  toxicology
Flow Cytometry, Fluorescence microscopy, Fluorescent detection | Print as PDF
 
ENZ-51035-0025 25 tests 142.00 USD
 
ENZ-51035-K100 100 tests 409.00 USD
Do you need bulk/larger quantities?
 

ROS-ID® Total ROS/Superoxide detection kit 

Widely cited kit to detect total ROS and Superoxide in live cells by microscopy and flow cytometry applications
Flow Cytometry, Fluorescence microscopy, Fluorescent detection, HTS | Print as PDF
 
ENZ-51010 1 Kit 329.00 USD
Do you need bulk/larger quantities?
 

NUCLEAR-ID® Red cell cycle kit (GFP-CERTIFIED®) 

Convenient kit for studying cell cycle progression by various applications
Flow Cytometry, Fluorescence microscopy | Print as PDF
 
ENZ-51008-100 1 Kit 447.00 USD
Do you need bulk/larger quantities?
 

NUCLEAR-ID® Red DNA stain 

Cell permeable DNA stain that can be used for a wide range of applications
≥93% (HPLC), Flow Cytometry, Fluorescent detection | Print as PDF
 
ENZ-52406 200 µl 426.00 USD
Do you need bulk/larger quantities?
 

NUCLEAR-ID® Blue/Green cell viability reagent 

Distinguishes between live vs dead cells in a single reagent.
≥93% (HPLC), Flow Cytometry, Fluorescence microscopy, Fluorescent detection | Print as PDF
 
ENZ-53004-C100 100 µl 325.00 USD
Do you need bulk/larger quantities?
 

NUCLEAR-ID® Blue/Red cell viability reagent (GFP-CERTIFIED®) 

Distinguishes between live vs dead cells in a single reagent.
≥93% (HPLC), Flow Cytometry, Fluorescence microscopy, Fluorescent detection | Print as PDF
 
ENZ-53005-C100 100 µl 313.00 USD
Do you need bulk/larger quantities?
 

NUCLEAR-ID® Red/Green cell viability reagent 

Distinguishes between live vs dead cells in a single reagent
≥93% (HPLC), Flow Cytometry, Fluorescence microscopy, Fluorescent detection | Print as PDF
 
ENZ-53006-C100 100 µl 319.00 USD
Do you need bulk/larger quantities?
 

NUCLEAR-ID® Green chromatin condensation detection kit  

A highly permeable green-emitting  dye for enhanced detection of apoptosis-induced chromatin condensation
Flow Cytometry, Fluorescence microscopy, Fluorescent detection | Print as PDF
 
ENZ-51021-K200 1 Kit 372.00 USD
Do you need bulk/larger quantities?
 

Cell Counting Kit-8 

Simple, fast and accurate assay to measure cell proliferation and cytotoxicity
Colorimetric detection | Print as PDF
 
ALX-850-039-0100 100 tests 103.00 USD
 
ALX-850-039-KI01 500 tests 222.00 USD
 
ALX-850-039-KI02 5x500 tests 660.00 USD
Do you need bulk/larger quantities?
 

FLUOFORTE® Calcium assay kit  

A Brighter, More Robust Fluorescent Assay for Calcium Mobilization
Flow Cytometry, Fluorescence microscopy, Fluorescent detection, HTS | Print as PDF
 
ENZ-51016 100x96 tests 3,206.00 USD
Do you need bulk/larger quantities?
 

FLUOFORTE® Calcium assay kit  

A Brighter, More Robust Fluorescent Assay for Calcium Mobilization
Flow Cytometry, Fluorescence microscopy, Fluorescent detection, HTS | Print as PDF
 
ENZ-51017 10x96 tests 434.00 USD
Do you need bulk/larger quantities?
 

GFP-CERTIFIED® FLUOFORTE® Calcium assay kit 

A brighter, more robust and GFP-compatible (orange dye) fluorescent assay for calcium mobilization
Flow Cytometry, Fluorescence microscopy, Fluorescent detection, HTS | Print as PDF
 
ENZ-51020-KP010 10x96 wells 582.00 USD
 
ENZ-51020-KP100 100x96 wells 4,090.00 USD
Do you need bulk/larger quantities?
 

ROS-ID® Hypoxia/Oxidative stress detection kit 

Widely cited kit for the simultaneous analysis of hypoxia and oxidative stress by microscopy and flow cytometry applications
Flow Cytometry, Fluorescence microscopy, Fluorescent detection, HTS | Print as PDF
 
ENZ-51042-0125 125 tests 136.00 USD
 
ENZ-51042-K500 500 tests 476.00 USD
Do you need bulk/larger quantities?
 

SCREEN-WELL® Wnt Pathway library 

Compounds are highly relevant; many are unique
HTS | Print as PDF
 
BML-2838-0100 1 Library 100 µl/well 1,882.00 USD
 
BML-2838-0500 1 Library 500 µl/well 4,507.00 USD
Do you need bulk/larger quantities?
 

Recommend this page