- Cost-efficient alternative to competitor's Lp-PLA2 detection system
- Wide analytical measurement range from 0 - 400.0 nmol/min/mL
- Analytical sensitivity of 0.236 nmol/min/mL
- High specificity and reproducibility, lot-after-lot
- Ready-to-use calibration standards and QC controls are provided
- Designed to run on automated clinical chemistry analyzers
The PLAQPRO™ Lp-PLA2 Assay measures the enzyme activity of Lp-PLA2 (lipoprotein-associated phospholipase A2) in serum samples. The assay is designed to run on automated clinical chemistry analyzers.
Please mouse over
Product Details
Sensitivity: | 0.236 nmol/min/mL |
|
Applications: | Colorimetric detection, HTS
|
|
Application Notes: | For the measurement of enzyme activity of Lp-PLA2 (lipoprotein-associated phospholipase A2) in serum samples. |
|
Species reactivity: | Human
|
|
Use/Stability: | Store all components, with the exception of Reagent 1, at -80°C until the kit’s expiration date. Reagent 1 may be stored at or below -20°C. Once thawed, the components can be stored at 2-8°C for up to 4 weeks. |
|
Handling: | Avoid freeze/thaw cycles. |
|
Shipping: | Blue Ice |
|
Contents: | Lp-PLA2 assay buffer
Lp-PLA2 assay substrate
5 calibrator standards
QC low control
QC high control |
|
Scientific Background: | Approximately two-thirds of heart attacks and strokes are caused by the rupture of an unstable, rupture-prone atherosclerotic plaque. Unstable plaques are characterized by high levels of inflammatory cells and inflammatory mediators.
Lipoprotein-associated phospholipase A2 (Lp-PLA2) is produced by inflammatory cells and circulates primarily bound to low-density lipoprotein (LDL) and is to a lesser extent associated with high-density lipoprotein (HDL) in human plasma. LDL oxidation is an early key event in the pathogenesis of atherosclerosis. Elevated Lp-PLA2 levels have been found in atherosclerotic plaques and rupture lesions. |
|
Technical Info/Product Notes: | The PLAQPRO™ Lp-PLA2 Assay is a colorimetric readout enzyme activity assay. During the test, Lp-PLA2 in serum samples hydrolyze the SN2 position of the substrate, 1-myristoyl-2-(4-nitrophenylsuccinyl)phosphatidylcholine. The resulting colored reaction product, 4-nitrophenol, is measured spectrophotometrically and the rate of formation of 4-nitrophenol is determined over successive measurements.
The assay kit includes five Lp-PLA2 calibrator standards for use in generating a standard curve fit of change in absorbance versus Lp-PLA2 activity level in nmol/min/mL. The activity of Lp-PLA2 in serum samples is interpolated from the calibration curve. |
|
UniProt ID: | Q13093 |
|
Regulatory Status: | RUO - Research Use Only |
|
Product Literature References
Endothelial Dysfunction in Children With Obstructive Sleep Apnea Is Associated With Elevated Lipoprotein-Associated Phospholipase A2 Plasma Activity Levels: L. Kheirandish-Gozal, et al.; J. Am. Heart Assoc.