Online Purchasing Account You are logged on as Guest. LoginRegister a New AccountShopping cart (Empty)
United States 

NUCLEAR-ID® Green cell cycle kit

Cell Cycle Results Independent of Incubation Time, Temperature, Dye and Cell Concentrations
 
ENZ-51014-100 1 Kit 398.00 USD
Do you need bulk/larger quantities?
 
  • Easy staining protocol, simply add the dye and analyze by flow cytometry
  • Excited using common 488 nm laser source, generating a green ~530 nm emission
  • No permeabilization step or RNase treatment necessary
  • Cell cycle results independent of incubation time, temperature, dye and cell concentrations
  • Provides DNA content information in live or fixed cells
  • Monitor changes in cell cycle dynamics arising from drug treatment or other perturbations
  • Performance validated using a wide range of cell densities
NUCLEAR-ID® Green Cell Cycle Analysis Kit provides a convenient approach for studying the induction and inhibition of cell cycle progression by flow cytometry. The kit is suitable for (1) determining the percentage of cells in a given sample that are in G0/G1, S and G2/M phases, as well as to quantify cells in the sub-G1 phase prior to apoptosis, and (2) DNA studies in live, permeabilized and fixed cells for normal cell lines and cell lines exhibiting multiple ploidy levels. The kit contains sufficient reagents for approximately 100 flow cytometry assays. A control cell cycle perturbation agent, Nocodazole, is provided for monitoring changes in cell cycle dynamics. Potential applications for live-cell studies are in the determination of cellular DNA content and cell cycle distribution for the detection of variations in growth patterns, for monitoring apoptosis, and for evaluating tumor cell behavior and suppressor gene mechanisms.

Product Details

Applications:Flow Cytometry, Fluorescence microscopy
 
Application Notes:This kit is suitable for DNA studies in live, permeabilized and fixed cells for normal cell lines and cell lines exhibiting multiple ploidy levels.
 
Quality Control:
  1. Absorption peak of NUCLEAR-ID® Green dye: λmax = 507 ± 4 nm
  2. % purity of NUCLEAR-ID® Green dye by HPLC: ≥93%
  3. A sample from each lot of NUCLEAR-ID® Green Cell Cycle Analysis Kit is used to analyze Jurkat cells using the procedures described in the user manual. Cells with Nocodazole gave %G2 value of >50%. Untreated cells gave the following results: (a) G0/G1 peak CV < 15%; (b) %G1 > 35%; (c) %G2 < 30%; and (d) G2/G1 ratio > 1.72.
 
Quantity:100 assays
 
Handling:Protect from light. Avoid freeze/thaw cycles.
 
Shipping:Dry Ice
 
Short Term Storage:-20°C
 
Long Term Storage:-80°C
 
Contents:NUCLEAR-ID® Green Cell Cycle Detection Reagent, 100 µl
Nocodazole Control, 10 µl
10X Assay Buffer, 15 ml
 
Technical Info/Product Notes:The NUCLEAR-ID® Green cell cycle analysis kit is a member of the CELLESTIAL® product line, reagents and assay kits comprising fluorescent molecular probes that have been extensively benchmarked for live cell analysis applications. CELLESTIAL® reagents and kits are optimal for use in demanding imaging applications, such as confocal microscopy, flow cytometry and HCS, where consistency and reproducibility are required .
 
Regulatory Status:RUO - Research Use Only
 

Product Literature References

Transcriptomic and functional studies reveal miR-431-5p as a tumour suppressor in pancreatic ductal adenocarcinoma cells: O.P. Haugen, et al.; Gene 822, 146346 (2022), Abstract;
Low‐intensity pulsed ultrasound stimulation promotes osteoblast differentiation through hedgehog signaling: K. Matsumoto, et al.; J. Cell. Biochem. 119, 4352 (2018), Abstract;
Nifurtimox reduces N-Myc expression and aerobic glycolysis in neuroblastoma: K.M. Cabanillas Stanchi, et al.; Cancer Biol. Ther. 16, 1353 (2015), Application(s): Flow cytometry using neuroblastoma cells, Abstract; Full Text

General Literature References

DNA measurement and cell cycle analysis by flow cytometry: R. Nunez; Curr. Issues Mol. Biol. 3, 67 (2001), Abstract;
Methods in Cell Biology, Flow Cytometry: Z. Darzynkiewicz, H.A. Crissman and J.P. Robinson (editors and co-authors); Vol. I and II, (1994), Book,

Related Products

NUCLEAR-ID® Red cell cycle kit (GFP-CERTIFIED®) 

Convenient kit for studying cell cycle progression by various applications
Flow Cytometry, Fluorescence microscopy | Print as PDF
 
ENZ-51008-100 1 Kit 447.00 USD
Do you need bulk/larger quantities?
 

Related Literature

Brochures
Monitor programmed cell death from membrane to nucleus
Monitor programmed cell death from membrane to nucleus
Download as PDF

Brochures
Live Cell Analysis
Live Cell Analysis
Download as PDF

Catalogs
Genomics & Molecular Biology
Genomics & Molecular Biology
Download as PDF

Brochures
Predictive Toxicology
Predictive Toxicology
Download as PDF

Scientific Posters
Evaluating Small Molecule Cell Cycle and Chromatin Condensation Modulators Using a Novel Green Fluorescent DNA-Binding Probe: Potential Application to Compound Screening
Evaluating Small Molecule Cell Cycle and Chromatin Condensation Modulators Using a Novel Green Fluorescent DNA-Binding Probe: Potential Application to Compound Screening
Download as PDF

Product Flyers
New Tools for Flow Cytometry
New Tools for Flow Cytometry
Download as PDF

All new literature pieces